Home Optical Knowledge

How to Determine Which Surface Quality Grade Your Optical System Requires

2026-11-24
When selecting optical lenses and windows for our customers, we are often asked the same question: "What is the highest surface quality you can achieve?" — This is actually a question that needs to be turned around. Surface quality grades (such as scratch-dig numbers) are essentially the "visibility" or size limit of defects, and whether they matter, and to what extent, depends entirely on the role the lens plays in your optical path. The higher the grade, the more screening costs, scrap rates, and processing hours rise — over-specifying only means you pay for performance you won't use.

Below are four steps that Zoolied recommends for making this determination.

Step 1: Distinguish Surface Quality from Surface Roughness

Scratch-Dig: Such as 60-40, 40-20, describing discrete, macroscopic defects visible to the naked eye (scratches, digs), relating to appearance, stray-light hot spots, and laser damage initiation.

Surface Roughness (RMS): Describing continuous microscopic undulations, typically measured in nanometers (nm), relating to scattering loss and imaging contrast.

Decision logic: If your concern is "are there scratches or pits on the lens," check scratch-dig; if your concern is "the image looks hazy, contrast won't come up," or "reflectance doesn't meet spec after coating," check roughness.

Step 2: Assess the Lens's Sensitive Position in the Optical Path

The severity of defect impact changes sharply with position.

Highly sensitive zones (grades must be tightened):

Near the image plane or focal plane: Scratches or digs here are directly "seen" by the imaging system and projected onto the sensor or sample, typically requiring 40-20 or better (e.g., 20-10).

In high-power laser paths: Surface defects modulate the optical field, creating local hot spots that induce laser damage. This is a hard safety requirement, not an appearance requirement. Lenses involving high-power lasers typically must use precision grade (e.g., 40-20 or 20-10), with attention to subsurface damage.

High-magnification microscope objectives or low-light imaging: If surface roughness exceeds approximately 10 nm, stray light will significantly degrade image-plane contrast, especially in high-numerical-aperture systems.

Relatively insensitive zones (grades may be relaxed):

In collimated beams far from the focal plane: If the lens is only used to fold the optical path and is not on an imaging plane, standard grade 60-40 is usually sufficient. Over-specification yields negligible improvement in system performance.

Step 3: Reference Typical Application Benchmarks (But Verify)

In the absence of system simulation data, industry conventions can serve as a starting point, but must be confirmed against your specific requirements.

Application Typical Surface Quality Reference Core Logic
General imaging, illumination, non-focal-plane filters 60-40 Defects are far from sensitive surfaces; standard grade meets most needs
Precision imaging, laser mirrors/lenses, low-light systems 40-20 Balances performance and cost; a common threshold for lasers and demanding imaging
High-precision windows, sensitive detector windows, high-power lasers 20-10 or tighter Defects must be small enough to avoid scattering hot spots or direct imaging defects
Note: The "60" in 60-40 is not the actual scratch width in micrometers, but a visibility grade compared against a standard sample plate. Therefore, different suppliers may have slight differences in the actual appearance of the same number; for critical systems, it is best to use a physical sample or clearly defined inspection conditions as the reference.

Step 4: Reverse-Justify the Grade Using Cost Trade-offs

Finally, we suggest you do the math: each step up in surface quality grade (e.g., from 60-40 to 40-20) increases screening costs, scrap rates, and processing hours. You can ask yourself directly: "If 60-40 is allowed, what specific measurable performance degradation will the system experience (e.g., how much SNR drops, how much laser damage threshold decreases)? If you can't say, then 60-40 is probably sufficient." Conversely, if you can clearly state "the lens is on the focal plane, and digs will be imaged," then you must tighten the grade.

One-Sentence Summary

Tell us where the lens sits, how strong the light is, and how far the image plane is from it. If it is not on the focal plane, doesn't handle high-power lasers, and doesn't participate in high-contrast imaging, standard grade is usually sufficient; if it meets even one of these conditions, move toward precision or high-precision grade. Zoolied's engineering team can help you select a surface quality grade that meets performance requirements without wasting cost, based on your specific optical path conditions.